Foam Board / Continuous Insulation

Johns Manville Polyiso foam continuous insulation boards provide a layer of insulation to reduce thermal bridging and improve energy efficiency. Polyiso consists of a uniform closed-cell polyisocyanurate foam core and provides one of the highest R-values per inch of any rigid insulation.

Filter Products By
  • Properties
  • Construction
  • Application Areas
With exceptional heat, moisture and air control, Johns Manville AP™ Foil-Faced Polyiso Foam Sheathing eliminates all major thermal bridges that cause heat loss when installed correctly.

Johns Manville AP™ Foil-Faced Polyiso Foam Sheathing boards are available in R-Values up to R-28 and offer a reflective foil facer on one side and a non-reflective facer on the other. AP Foil provides exceptional heat, moisture and air control and, when installed correctly, eliminates all major thermal bridges that cause heat loss. The rigid continuous insulation board allows for maximum wall and worksite efficieny.

APFoil_LG 190x122

Advantages

Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-28.
Water-Resistive Barrier: Meets the ICC-ES AC71 acceptance criteria.
Vapor Barrier: Class I vapor retarder at one inch.
Air Barrier: Meets the Air Barrier Association of America boardstock criteria, when properly installed.
Lightweight: Easy to handle and may be cut with a utility knife or saw.

  ASTM Standards   ASTM C1289   Type I, Class 1
  Flame Spread   ASTM E84   4": ≤ 25
  Smoke Development   ASTM E84   ≤ 450
  Water Vapor Transmission   ASTM E96   0.05 perms (3 ng/Pa-s-m2)
  Compressive Strength   ASTM D1621   ≥ 16 psi (110 kPa)
  Water Absorption   ASTM C209   0.1% volume
  Service Temperature      -100 to 250°F
  R-Value Per Inch     6.0

Data Sheet

AP Foil-Faced Foam Sheathing Data Sheet

SDS

AP Foil-Faced Foam Sheathing SDS
AP Foil-Faced Foam Sheathing SDS (ES)

Installation Instructions

JM Continuous Insulation Wall System Installation Guide 
Technical Bulletin 302: Wall Bracing with Polyiso CI 
JM AP Foil Faced Sheathing Below-Grade Interior Walls Installation Instructions
JM AP Foil Faced Sheathing Below-Grade Exterior Walls Installation Instructions
JM AP Foil Faced Sheathing Crawl Spaces Installation Instructions
AP Foil Faced Insulation Sheathing Board Attics and Cathedral/Vaulted Ceiling Installation Instructions
AP Foil Residential Installation Instructions - Above Grade Exterior Walls,Technical Guide

Technical Bulletin

JM AP Foil - NFPA 285 Wall Assemblies

STC Rating Documents

Acoustical Assemblies STC Rating Reference Guide

Wall Assemblies

Continuous Insulation for Stucco Wall Systems - Option One
Continuous Insulation for Stucco Wall Systems - Option Two
Continuous Insulation for Stucco Wall Systems - Option Three
Continuous Insulation Wall System

Continuous Insulation

Continuous Insulation Website
Technical Bulletin 301: Polyiso CI Performance in Residential Wall Applications   
Technical Bulletin 303: Moisture Control with Polyiso CI       
Technical Bulletin 304: Energy Efficiency with Polyiso CI

Evaluation Reports

CCRR-0444

Literature

Product Selector Guide
JM All-Purpose Wall System Sell Sheet
PIMA - Polyiso Wall Insulation Boards EPD
PIMA Performance Bulletin - Polyiso vs. XPS
JM All-Purpose Wall System Components Sheet
NFPA 285 ACM Assemblies Announcement

Certifications and Specifications

JM Continuous Insulation Wall System Specification, Section 072100 - Foil Faced Rigid Insulation
Polyiso Sheathing EPD

Case Study

JM Castle Pines Case Study
Vision House Case Study

Warranties

AP Foil and CI Max 20 Year Limited Warranty


JM Foam Board Video


JM Overview Video


JM Continuous Insulation Video


Polyiso Continuous Insulation Wall Systems: The Perfect Wall

JM CI and Building Science

(webinar)

Available Documents

Designed for easy installation in exposed interiors, Johns Manville CI Max® Polysio Foam Continuous Insulation is ideal for places where high efficiency is required.

Johns Manville CI Max® Polyiso Foam Continuous Insulation is available in R-Values up to R-26 and provides a layer of insulation to reduce thermal bridging and improve energy efficiency. CI Max Continuous Insulation is designed for exposed interior applications and is approved for use without a thermal barrier. It is suitable for wall or ceiling applications in residential, commercial, agricultural and industrial buildings. 

CI_MAX_APFoil_DSCI0560_RT_CMYK 190x122

Advantages

Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-26.
Vapor Barrier: Maintains a minimum thickness of one inch and qualifies as a Class I vapor retarder.
Lightweight: Easy to handle and may be cut with a utility knife or saw.

  ASTM Standards   ASTM C1289   Type I, Class 1
  Flame Spread   ASTM E84   4": ≤ 25
  Smoke Development   ASTM E84   ≤ 450
  Water Vapor Transmission   ASTM E96   0.02 perms (1.4 ng/Pa-s-m2)
  Compressive Strength   ASTM D1621   ≥ 16 psi (110 kPa)
  Water Absorption   ASTM C209   < 0.6% volume
  Service Temperature      -100 to 250°F
  R-Value Per Inch     6.0

Data Sheet

CI Max Foam Sheathing Data Sheet

SDS

CI Max Foam Sheathing SDS
CI Max Foam Sheathing SDS (ES)

Installation Instructions

CI Max for Exposed Interior Use

Warranties

AP Foil and CI Max 20 Year Limited Warranty

Literature

Product Selector Guide
PIMA - Polyiso Wall Insulation Boards EPD
PIMA Performance Bulletin - Polyiso vs. XPS
JM All-Purpose Wall System Components Sheet

Evaluation Reports

CCRR-0444

Certifications and Specifications

JM CI Max Guide Specifications in CSI Format
JM Continuous Insulation Wall System Specification, Section 072100 - Foil Faced Rigid Insulation
Polyiso Sheathing EPD


JM Foam Board Video


JM Continuous Insulation Video


JM Overview Video


Polyiso Continuous Insulation Wall Systems: The Perfect Wall

Available Documents

A rigid roof insulation board with high thermal efficiency, Johns Manville R-Panel® is compatible with multiple types of membrane systems.

Johns Manville R-Panel® rigid roof insulation board offers R-Values of up to R-23.6, providing high thermal efficiency. R-Panel is manufactured with a closed-cell polyisocyanurate foam core bonded to fiberglass-reinforced facers and designed for use over metal, nailable and non-nailable roof decks with a variety of membrane systems. R-Panel meets the International Building Code requirements for a foamed plastic roof insulation.

JM_ 100748 190x122

Advantages

Thermally Efficient: Effective resistance to heat transfer, with R-values up to R-23.6.
Universal Facer: Compatible with BUR, modified bitumen and single-ply membrane systems.
Clean Air: Meets Clean Air Act Amendments of 1990.
Miami-Dade County Product Control Approved:
Complies with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.
Lightweight: Easy to handle and may be cut with a utility knife or saw.

  ASTM Standards   ASTM C1289-01   Type II, Class I, Grade 2
  Flame Spread   ASTM E84   ≤ 75
  Smoke Development   ASTM E84   ≤ 450
  Water Vapor Transmission   ASTM E96   < 1 perms (57.5 ng/Pa-s-m2)
  Compressive Strength   ASTM D1621   ≥ 20 psi (138 kPa)†
  Dimensional Stability   ASTM D2126   2% max, 7 days (length & width)
  Water Absorption   ASTM C209   < 1% volume
  Service Temperature     -100 to 250°F
  R-Value Per Inch     5.7 LTTR

Data Sheet

R-Panel Roof Insulation Data Sheet

SDS

R-Panel Roof Insulation SDS
R-Panel Roof Insulation SDS (ES)

Literature

Product Selector Guide

Available Documents